Fractionation / Separation / Extraction / Filtration
Fractionation / separation / extraction / filtration refers to various instruments and accessories used for sample separation / extraction / filtration. It is used in many fields such as medical and scientific experiments and research, water quality testing and sterilization testing, and analytical testing of food and beverages. In addition to filter paper, which is commonly used to detect substances present in samples, there are a variety of products tailored to the target sample and purpose, such as filters, funnels, centrifuges, and chromatograph tubes.
Other Related Pages
- ADVANTEC Round Qualitative Filter Paper No.1Among the qualitative filter papers, it is a filter paper with a high filtration rate. Suitable for filtering coarse precipitates such as iron hydroxide. It corresponds to one type specified in JIS P 3801 [Filter paper (for chemical analysis)]. The raw material is α-cellulose (pure cellulose with... Read MoreAsh 0.10% Thickness (mm) 0.2 Operating pH Range 0~12 Specification 1 packaging: 100 sheets Maximum Operating Temperature (℃) 120 Drainage Time (s) 45 Particle Retention Capacity (μm) 6 Burst Strength (kPa) 79 Water Absorption (cm) 9 Mass (g/m2) 90 JIS Standard JIS P 3801 Class 1
- ADVANTEC Glass Filter Paper GS-25Ultra-fine borosilicate glass fiber is treated with an organic binder (acrylic resin) to increase its strength and make it easier to handle. It has low hygroscopicity, tends to become constant when dried, and has excellent dimensional stability. The hole diameter is about 1 μm. It is used as a ta... Read MoreThickness (mm) 0.21 Pressure Loss (kPa) 0.32 Retained Particle Size (μm) 0.6 Maximum Operating Temperature (℃) 120 Drainage Time (s) 15 Basis Weight (g/m2) 70 Collection Efficiency (%) 99.9(0.3μmDOP%) Material Borosilicate glass fiber
- KENIS Visking Tubing (for Dialysis)● Almost permanent resistance to water. Water and small molecules permeate freely, but do not permeate macromolecular compounds such as proteins, bacteria, etc. This product can be used for concentration, desalting, and dialysis. Concentration / desalination / dialysisMolecular weight cut off 10000-14000 (24 angstrom pore size)
- Artec Qualitative Filter Paper No.1Most often used for general purposes.Particle Retention Capacity (μm) 6
- ADVANTEC Circular Hard Filter Paper No.4ASince the surface of the filter paper is hardened by chemical treatment, the paper quality is tough and the surface is smooth, and there is almost no fiber detachment. Suitable for pressurization and vacuum filtration. It is relatively resistant to acids and alkalis and repairs fine precipitates.... Read MoreAsh 0.025% Thickness (mm) 0.12 Operating pH Range 0~14 Particle Retention Capacity (μm) 1 Maximum Operating Temperature (℃) 120 Burst Strength (kPa) 224 Water Absorption (cm) 4.0 Drainage Time (s) 915 Mass (g/m2) 96 JIS Standard JIS P 3801 4 typesfrom S$14.99Min. 2 days
- ADVANTEC Syringe filter DISMIC JP typeA disposable filter unit that incorporates a PTFE type membrane filter. Suitable for small amount filtration of various organic solvents. It is a combination of a PTFE type membrane filter and a polypropylene housing, and has chemical resistance. Since the filter is hydrophobic, it can also be us... Read MoreMaximum Operating Pressure (MPa) 0.51from S$159.90Min. 2 days
- ADVANTEC Qualitative filter paper No.2The raw material is cellulose fiber with 99% or more of α-cellulose. It is commonly used in qualitative analyses that retain the precipitate well and require precision.Ash 0.1% Thickness (mm) 0.26 Operating pH Range 0~12 Maximum Operating Temperature (℃) 120 Burst Strength (kPa) 122 Mass (g/m2) 125 Particle Retention Capacity (μm) 5 Water Absorption (cm) 8 break strength, when wet (kPa) 8 Drainage Time (s) 80 JIS Standard JIS P 3801 Type 2from S$5.69Min. 2 days
- ADVANTEC Qualitative Filter Paper No.1The raw material is cellulose fiber with 99% or more of α-cellulose. It has a high filtration rate and is suitable for filtering coarse precipitates such as iron hydroxide.Ash 0.1% Thickness (mm) 0.2 Operating pH Range 0~12 Maximum Operating Temperature (℃) 120 Drainage Time (s) 45 Particle Retention Capacity (μm) 6 break strength, when wet (kPa) 7 Burst Strength (kPa) 79 Water Absorption (cm) 9 Mass (g/m2) 90 JIS Standard JIS P 3801 Class 1
- ADVANTEC Filter Paper for Water Absorption No.26-WAWater-absorbing filter paper No.26-WA is a smooth, highly water-absorbent filter paper made of pure cellulose fibers. Suitable for suction paper for hand-made paper test specified in TAPPI (Technical Association of the Pulp and Paper Industry) T205. * Water absorption: The height of water that ri... Read MoreThickness (mm) 0.7 Water Absorption (cm) 11 Maximum Operating Temperature (℃) 120 Mass (g/m2) 325from S$76.99Min. 2 days
- ADVANTEC Laminated paperAlthough the filter paper surface absorbs liquid quickly, it does not penetrate or leak into the laminated surface (back surface), so it is possible to prevent radioactive liquid from penetrating into the working environment in the nuclear field, and to use chemicals in general laboratories as a ... Read MoreThickness (mm) 0.2 Mass (g/m2) 100 Water Retention Rate (%) 200 or more Width x Length (mm×m) 810×33from S$179.90Min. 2 days
- GE Healthcare Double Ring Qualitative Filter Paper MEDIUM102You can select filter paper with specifications equivalent to JIS standards 1 to 3. Widely used for detection and identification of substances contained in samples. A product lineup that supports filtration from coarse particles such as colloidal precipitates to fine precipitates. Suitable for fi... Read MoreThickness (μm) 158 Basis Weight (g/m2) 80.0±4.0 Retained Particle Size (μm) About 10 JIS Standard JIS P 3801 2 class equivalent Ash content (%) ≦0.11 Filtration speed >35to≦70(s)from S$4.79Min. 2 days
- Whatman Qualitative Filter Paper # 2Compared to Grade 1, it features high retention and high absorbency. The filtration rate will be slightly slower. As an example of use that makes the best use of absorbency, it can also be used to retain soil nutrients during plant growth tests. It can also be used to monitor certain impurities i... Read MoreAsh 0.06% Thickness (mm) 0.19 Quantity (Sheets) 100 JIS Standard 2 types equivalent Drainage Time (s) 55 (initial) Particle Retention Capacity (μm) 8 Mass (g/m2) 97 Specification Domestic filter paper equivalent No.2 Suitable Products Domestic filter paper: No.2from S$12.99Min. 2 days
- KIRIYAMA GLASS Kiriyama Rohto Filter Paper No.3Ash 0.0001g Thickness (mm) 0.23 Retained Particle Size (μm) 5 Filter Paper No.3 Filtration speed Slightly fasterfrom S$11.99Min. 2 days
- Matsuyoshi & Co Compact IncubatorsHigh-precision temperature control by microcomputer PID control. The temperature inside the refrigerator and the set temperature are displayed digitally in two stages. The door can be opened to the right or left. It can be easily replaced.Setting Temperature (℃) (Room temperature +5)-60 Power Consumption (W) 100 Mass (kg) 17 Matsuyoshi & Co., Ltd. Code 23-3222-00 Effective Internal Dimensions, W x D x H (mm) 330×300×360 Internal Capacity (L) 35 Dimensions, Width W x Depth D x Height H (mm) 412×374×515 Power Supply AC100V 50/60Hz Included Accessories Stainless steel shelf x 2from S$979.90Min. 2 days
- Whatman Qualitative Filter Paper No.42 (Circle)Filter Paper 42 Filter Paper No. 5C (Similar domestic number) Type Roundfrom S$33.99Min. 5 days
- Thermo Fisher Scientific Mini centrifugeIncludes rotors for microtubes and PCR tubes. When the lid is opened, it automatically stops, and when it is closed, the operation resumes.Dimension (mm) 128×153×104 Maximum Centrifugal Force (xg) 2000 Maximum Rotation Speed (min-1[rpm]) 6000 (fixed) Mass (g) 815 Power Supply AC110~120V・50/60Hzfrom S$599.90Min. 2 days
- GE Healthcare Double Ring Quantitative Filter Paper SLOW203You can select filter paper with specifications equivalent to JIS standard 5 type A to 5 type C. Supports a wide range of applications such as weight analysis and food or soil analysis. Smooth surface, very low ash content, high particle retention. It is used in a wide range of applications such ... Read MoreThickness (μm) 150 Basis Weight (g/m2) 80.0±4.0 Retained Particle Size (μm) About 3 JIS Standard JIS P 3801 Class 5 C equivalent Ash content (%) ≦0.009 Filtration speed >70to≦140(s)
- AS ONE Qualitative Filter PaperFilter Paper 102 Mass (g/m2) 80±4 Material cellulosefrom S$6.49Min. 4 days
- ADVANTEC Quantitative filter paper No.6The raw material is cellulose fiber with 99% or more of α-cellulose. Pure cellulose fibers are treated with hydrochloric acid and hydrogen fluoride to reduce the distribution content to a low level of about 0.01%, enabling accurate quantitative analysis. It is commonly used as a quantitative filt... Read MoreAsh 0.01% Thickness (mm) 0.2 Operating pH Range 0~12 Mass (g/m2) 103 break strength, when wet (kPa) 12 Maximum Operating Temperature (℃) 120 Particle Retention Capacity (μm) 3 Drainage Time (s) 300 Burst Strength (kPa) 49 Water Absorption (cm) 6 JIS Standard JIS P 3801 6 typesfrom S$139.90Min. 7 days
- AS ONE Quantitative Filter PaperFilter Paper 202 Mass (g/m2) 80±4 Material cellulosefrom S$16.99Min. 4 days
- MS(Membrane Solutions) Syringe Filter Membrane / PVDFIt has extremely low adsorption of hydrophobic proteins and exhibits chemical resistance to a wide range of organic solvents. Suitable for gas / steam / high temperature filtration, food filtration, etc. Autoclave sterilization possibleSize (mm) 30 Material Membrane / PVDFfrom S$169.90Min. 13 days
- KENIS Whatman Qualitative Filter PaperA general-purpose filter paper used to detect and identify substances contained in samples. Detection and identification of substances contained in the samplefrom S$13.99Min. 24 days
- Sigma-Aldrich TLC tank (with lid)A development tank used for thin layer chromatographs and paper chromatographs.Type Squarefrom S$279.90Min. 24 days
- AS ONE Exhaust Pipe Straight Pipe PTFE Cock VSF SeriesMaterial Borosilicate glass-1 Valve PTFE cock Type Straight pipe suction hole outer diameter (mm) Φ8from S$79.99Min. 4 days
- SANSYO Qualitative filter paper QL-BParticle Retention Capacity (μm) 15~20 Filtration speed 35 to 70 (Herzberg) (seconds) Mass (g/m2) 80±4 Ash ≦0.15%from S$4.59Min. 6 days
- ADVANTEC Square quantitative filter paper No.5ADimensions (cm) 56×48.5 TGK Part No. 567-40-02-85 Filter Paper No. No.5A Specification 1 packaging: 100 sheetsfrom S$569.90Min. 7 days
- SANSYO Qualitative filter paper QL-AFiltration speed <35 (Herzberg) (seconds) Particle Retention Capacity (μm) 20~25 Mass (g/m2) 80±4 Ash ≦0.15%from S$4.59Min. 6 days
- SANSYO Qualitative filter paper QL-CParticle Retention Capacity (μm) 10~15 Filtration speed 70-140 (Herzberg) (seconds) Mass (g/m2) 80±4 Ash ≦0.15%from S$4.59Min. 6 days
- Sigma-Aldrich TLC tank (with lid)A development tank used for thin layer chromatographs and paper chromatographs.Type Cylindricalfrom S$259.90Min. 24 days
- IKA Rotary Evaporator* Magnetic valve for vacuum control is sold separately.Output (W) (Heating) 1300 Type of Control (Heating) Microprocessor control Cooling area 1200cm2 Temperature setting unit 1℃ Mass (kg) 20 (No glass set with heating bath) Rotational Speed (min -1 [rpm]) 20~280 Main Unit Dimensions, Width W x Depth D x Height H (mm) 530 x 410 x 570 (without glass set) Allowable Ambient Temperature (℃) 5~40 Motor input (W) 75 Motor Type DC brushless motor Temperature Display Digital Rotational speed display method Digital Angle (°) Head adjustment width / 0 ~ 45 ° Protection Class IP20(DIN EN60529) Temperature Range (℃) Room temperature to 180 Control Temperature (℃) ±1from S$10,990.00Min. 6 days
- MS(Membrane Solutions) Syringe Filter Membrane / Cellulose Acetate CA Seriesγ sterilized. Hydrophilic. It has extremely low protein binding and is suitable for filtering aqueous protein solutions with high throughput. Suitable for filtration of nitric acid / groundwater and measurement of light scattering.Type gamma sterilizedfrom S$179.90Min. 4 days
- CLIMBING Flask for Normal Pressure Distillation Unit* Stand and clamp are sold separately.Ground Joint 19/38 Material Borosilicate glass-1from S$64.99Min. 16 days
- ADVANTEC Manifold KM seriesA manifold used when filtering multiple samples at the same time. * Wrap sealing tape around the tapered thread for piping.Suction diameter (Φmm) 11 (1/4 inch PT) Material SUS304 Valve Three-way cockfrom S$1,999.00Min. 5 days
- AS ONE Suction Filtration Pump Replacement Exhaust FilterAs ONE Part Number 3-6479-12 Type Replacement exhaust filterfrom S$33.99Min. 4 days
- Yazawa Kagaku TLC tankGlass expansion tank. HCG-100-7D can use a 200 x 200 mm plate, and HCG-80-7 can use a 100 x 100 mm plate. HCG-100-7D comes with a stainless steel frame.Inner Dimensions (width W x depth D x height H) (mm) 235×105×210 Standard With 3 standing framesfrom S$1,499.00Min. 9 days
- AS ONE Combination Jet ManifoldIt is a double manifold for viable cell count test. Compact design that connects directly to the Microsalt / e.jet pump. The quick connection makes it easy to attach and detach the tube. Compatible with various containers and funnels by replacing the filter base.from S$579.90Min. 13 days
Filter by categories