A general-purpose pressure switch that is highly evaluated for its reliability and durability.
For air conditioning, air conditioning, and various industrial equipment
Fluid Temperature (℃) -20~120 Operation Ambient Temperature (℃) -20~70 Mass (kg) 0.33 RoHS directive (corresponding to 10 substances) Correspondence
Easy-to-read 3-color LCD display. Easy setting with up / down buttons. The buttons are large and easy to operate. The cable is a connector method and can be easily attached and detached. Equipped with switch output and analog output as standard. Energy saving.
Shock Resistance (m/s2) 100 (10G) x YZ 3 times in each direction Current Consumption (mA) 40 or less (with no load) Withstand Voltage (V) AC10001 min (between lead wire and case) Suitable Fluid Air, non-corrosive, non-flammable gas Mass (g) Approx. 80 (including cable) Power Supply Voltage (V) DC12-24 (ripple ± 10% or less) Protection Class IP40 Operation Indicator Lamp Orange (1 & 2 indicator) OUT1 OUT2 Structure Silicon diaphragm Repeatability (%) ± 0.2FS ± 1digit or less
Operation Ambient Temperature (℃) -10 to +50, when stored / -10 to +60 Power Supply Voltage (V) 12-24 DC ± 10% Ripple P-P10% or less Mass (g) About 40 Suitable Fluid Air / non-corrosive gas Type of Connection Connector Element Diffusion semiconductor pressure sensor Short Circuit Protection Equipment Protection Class IP40(IEC) Hysteresis Minimum 1 digit (variable) Included Accessories PPX-C2 (2m connector cable) x 1 Output Operation Select NO/NC by key operation
Ambient Temperature (℃) 0 to +50 (However, no condensation) Fluid Temperature (℃) 0 to +70 (however, without freezing) Pressure range (MPa) 0~1.0 Withstand Pressure (MPa) 1.5 Response Time Approximately 500ms (alarm output) Flow direction Both directions Suitable Fluid Water Mounting Side freedom
Single unit specifications for various general-purpose mounting
Hysteresis (MPa) 0.08 or less Pressure Setting Range (MPa) 0.1~0.6 Maximum Operating Pressure (MPa) 1 Contact Configuration 1a Insulation Resistance 20MΩ or more at DC500V mega Shock Resistance (m/s2) 294 Voltage drop (V) 3 or less (internal) Load current (mA) 5~50、7~20 Ambient and Flowing Fluid Temperature (℃) 5~60 Suitable Fluid Compressed air Load Voltage (V) DC12/24、AC100 Protection Class IP65 equivalent Lamp Light-emitting diode (lights up when ON) Repeatability ± 0.02MPa or less
Operating Pressure Range (MPa) 0~1 Withstand Pressure (MPa) 1.5 Power supply 10.8 to 30 VDC (including ripple) Current Consumption (mA) 20 mA or less (24 VDC no load) Suitable Fluid Air, inert gas Operation Mode Analog output RoHS directive (corresponding to 10 substances) Correspondence Protection Class IEC standard IP40 equivalent Display Part No pressure display Type Positive pressure sensor
It converts the pressure into the thrust of the piston and turns the micro switch on and off. A signal is output when the pressure of compressed air reaches the set pressure. (BN-1217T-6 is a reed switch type)
Power supply 10.8 to 30 VDC (including ripple) Current Consumption (mA) 20 mA or less (24 VDC no load) Suitable Fluid Air, inert gas RoHS directive (corresponding to 10 substances) Correspondence Protection Class IEC standard IP40 equivalent Type Negative pressure sensor Display Part No pressure display
Power supply 10.8 to 30 VDC (including ripple) Current Consumption (mA) 20 mA or less (24 VDC no load) Suitable Fluid Air, inert gas RoHS directive (corresponding to 10 substances) Correspondence Protection Class IEC standard IP40 equivalent Display Part No pressure display Type Positive pressure sensor
Ambient Temperature (℃) -5 ~ 60 ℃ (No freezing) Pressure Adjustment Range (MPa) 0.1~0.8 Mass (kg) 0.57 Maximum Operating Pressure (MPa) 1.0 Assured Pressure Resistance (MPa) 1.5 Insulation Resistance (MΩ) 100 or more (at 500 VDC megger) Contact Configuration 1ab Allowable Operating Frequency (times / minute) 20 Fluid Temperature (℃) 5~60 Outer dimensions, Width W x Height H x Depth D (mm) 70.4×92×52.4 Ambient Humidity (% RH) 90 or less Mounting Direction Any Suitable Fluid Compressed air Shape of Switch Micro switch: Z-15GD-B (OMRON) Repeatability Within ± 0.020MPa against set pressure Material (Body) Zinc die cast
We have a lineup of products that support not only drive equipment but also pneumatic systems in detail, making them easier to use and expanding their applications. A small pressure switch for vacuum and positive pressure with excellent reliability and responsiveness. Easy operation with 2 screen... Read More
Operating Pressure Range (MPa) Low pressure type -0.10 to +0.10
Working pressure range (kPa) -100~0 Pressure Setting Range (MPa) -99~0 Display 0 to -99kPa (2-digit red LED display) Operating Temperature (℃) 0-50 (no freezing) Withstand Pressure (MPa) 0.2 Resolution 1digit Responsiveness 1m・sec max. Humidity Range (RH) 35 to 85% (non-condensing) Current Consumption (mA) 40 or less Display Format About 4 times / 1 second RoHS directive (corresponding to 10 substances) Correspondence Detection Method Diffusion semiconductor pressure switch Protection Class IEC standard IP40 equivalent Type Negative pressure sensor Display Part With LED display Display Accuracy ±3%F.S. ±2digit Accuracy ±3%F.S.max.(at Ta=25℃)
Operating Pressure Range (MPa) 0~1 Power supply 10.8 to 30 VDC (including ripple) Current Consumption (mA) 20 mA or less (24 VDC no load) Withstand Pressure (MPa) 200 Suitable Fluid Air, inert gas RoHS directive (corresponding to 10 substances) Correspondence Protection Class IEC standard IP40 equivalent Operation Mode NPN open collector output Type Negative pressure sensor Display Part No pressure display