Buy more than* S$200* and get FREE SHIPPING

S1DX Timer

4.57 (14)
Time Limit Contact
2c
Number of Pins
8
Caution
This product is manufactured in Japanese standards. Please check the specification before you order.
...see all>
Product Options
ADD TO CART
Rated Control Capacity Rated Power Consumption Operating Ambient Temperature (deg C) Rated Voltage (V) Model Number Terminal Shape Contact Resistance (mohm) Recovery Time Time Specification Impact Resistance Rated Frequency (Hz) Ambient Humidity Impact Resistance (Malfunction) Item Number Operating Mode Restriction Package
Qty.
Ship pack of Mfr.# Item.# Sales Price Availability Qty.
Rated Control Capacity Rated Power Consumption Operating Ambient Temperature (deg C) Rated Voltage (V) Model Number Terminal Shape Contact Resistance (mohm) Recovery Time Time Specification Impact Resistance Rated Frequency (Hz) Ambient Humidity Impact Resistance (Malfunction) Item Number Operating Mode Restriction Package
Qty.
Ship pack of Mfr.# Item.# Sales Price Availability Qty.
7A 250V AC (resistive load) 3VA following (Non-condensing) -10 to +50 AC100-120 S1DX-A2C3S-AC120V Plug-in termination Initial / 100 or less (DC6V1A) 0.1 seconds or less 0.1 to 3 seconds 980m / s <sup> 2 </ sup> (100G) or more 50/60 shared 80 - 85% RH (at20 deg C) 98m / s <sup> 2 </ sup> (10G) or more - ON-delay AC type   1PC 1 ADX11124 35286492 48.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) Less than 2W (Non-condensing) -10 to +50 DC24 S1DX-A2C3S-DC24V Plug-in termination Initial / 100 or less (DC6V1A) 0.1 seconds or less 0.1 to 3 seconds 980m / s <sup> 2 </ sup> (100G) or more - 80 - 85% RH (at20 deg C) 98m / s <sup> 2 </ sup> (10G) or more - ON-delay type DC   1PC 1 ADX11022 35286815 45.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) Less than 2W -10 to +50(Non-condensing) DC24 S1DX-A2C1S-DC24V Plug-in termination Initial / 100 or less (at DC6V1A) - - 980m / s <sup> 2 </ sup> (100G) or more - 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay type DC *[No return] You cannot return this product. For details, see FAQ. 1PC 1 ADX11002 35286806 45.99 SGD
Shipped after 2019-06-03
7A 250V AC (resistive load) Less than 2W -10 to +50(Non-condensing) DC12 S1DX-A2C10S-DC12V Plug-in termination Initial / 100 or less (at DC6V1A) - - 980m / s <sup> 2 </ sup> (100G) or more - 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay type DC   1PC 1 ADX11051 35286736 45.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) Less than 2W -10 to +50(Non-condensing) DC12 S1DX-A2C30S-DC12V Plug-in termination Initial / 100 or less (at DC6V1A) - 1-30 seconds 980m / s <sup> 2 </ sup> (100G) or more - 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay type DC *[No return] You cannot return this product. For details, see FAQ. 1PC 1 ADX11071 35286745 45.99 SGD
Shipped after 2019-06-03
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC100-120 - Plug-in termination Initial / 100 or less (at DC6V1A) 0.1 seconds or less 0.5 to 10min 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX11134 ON-delay AC type   1PC 1 S1DX-A2C10M-AC120V 35286553 48.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC100-120 - Plug-in termination Initial / 100 or less (at DC6V1A) 0.1 seconds or less 0.5 to 10s 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX11154 ON-delay AC type   1PC 1 S1DX-A2C10S-AC120V 35286517 48.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC200-220 - Plug-in termination Initial / 100 or less (at DC6V1A) 0.1 seconds or less 0.1 to 1s 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX11105 ON-delay AC type   1PC 1 S1DX-A2C1S-AC220V 35286605 48.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) Less than 2W -10 to +50(Non-condensing) DC24 S1DX-A2C10S-DC24V Plug-in termination Initial / 100 or less (at DC6V1A) - - 980m / s <sup> 2 </ sup> (100G) or more - 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay type DC   1PC 1 ADX11052 35286833 45.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) Less than 2W -10 to +50(Non-condensing) DC24 S1DX-A2C0.5S-DC24V Plug-in termination Initial / 100 or less (at DC6V1A) - - 980m / s <sup> 2 </ sup> (100G) or more - 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay type DC *[No return] You cannot return this product. For details, see FAQ. 1PC 1 ADX110A2 35286797 45.99 SGD
Shipped after 2019-06-03
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC200-220 - Plug-in termination Initial / 100 or less (at DC6V1A) 0.1 seconds or less 0.1 to 3h 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX11195 ON-delay AC type *[No return] You cannot return this product. For details, see FAQ. 1PC 1 S1DX-A2C3H-AC220V 35286702 48.99 SGD
Shipped after 2019-06-03
7A 250V AC (resistive load) Less than 2W -10 to +50(Non-condensing) DC12 S1DX-A2C10M-DC12V Plug-in termination Initial / 100 or less (at DC6V1A) - - 980m / s <sup> 2 </ sup> (100G) or more - 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay type DC *[No return] You cannot return this product. For details, see FAQ. 1PC 1 ADX11031 35286772 45.99 SGD
Shipped after 2019-05-30
7A 250V AC (resistive load) Less than 2W -10 to +50(Non-condensing) DC12 S1DX-A2C60M-DC12V Plug-in termination Initial / 100 or less (at DC6V1A) - 3 (60 minutes) 980m / s <sup> 2 </ sup> (100G) or more - 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay type DC *[No return] You cannot return this product. For details, see FAQ. 1PC 1 ADX11081 35286781 45.99 SGD
Shipped after 2019-06-03
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC200-220 - Plug-in termination Initial / 100 or less (at DC6V1A) - 0.05 to 0.5s 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX111A5 ON-delay AC type *[No return] You cannot return this product. For details, see FAQ. 1PC 1 S1DX-A2C0.5S-AC220V 35286596 48.99 SGD
Shipped after 2019-05-31
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC200-220 - Plug-in termination Initial / 100 or less (at DC6V1A) 0.1 seconds or less 0.5 to 10s 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX11155 ON-delay AC type   1PC 1 S1DX-A2C10S-AC220V 35286632 48.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC200-220 - Plug-in termination Initial / 100 or less (at DC6V1A) - 0.1 to 3min 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX11165 ON-delay AC type   1PC 1 S1DX-A2C3M-AC220V 35286666 48.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC200-220 - Plug-in termination Initial / 100 or less (at DC6V1A) 0.1 seconds or less 3 to 60min 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX11185 ON-delay AC type   1PC 1 S1DX-A2C60M-AC220V 35286693 48.99 SGD
Shipped after 2019-06-03
7A 250V AC (resistive load) Less than 2W -10 to +50(Non-condensing) DC12 S1DX-A2C3S-DC12V Plug-in termination Initial / 100 or less (at DC6V1A) - - 980m / s <sup> 2 </ sup> (100G) or more - 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay type DC   1PC 1 ADX11021 35286711 45.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) Less than 2W -10 to +50(Non-condensing) DC12 S1DX-A2C5S-DC12V Plug-in termination Initial / 100 or less (at DC6V1A) - - 980m / s <sup> 2 </ sup> (100G) or more - 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay type DC *[No return] You cannot return this product. For details, see FAQ. 1PC 1 ADX110E1 35286727 45.99 SGD
Shipped after 2019-08-22
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC200-220 - Plug-in termination Initial / 100 or less (at DC6V1A) 0.1 seconds or less 0.5 to 10min 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX11135 ON-delay AC type   1PC 1 S1DX-A2C10M-AC220V 35286675 48.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC100-120 - Plug-in termination Initial / 100 or less (at DC6V1A) - 0.1 to 1s 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX11104 ON-delay AC type   1PC 1 S1DX-A2C1S-AC120V 35286483 48.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC100-120 - Plug-in termination Initial / 100 or less (at DC6V1A) 0.1 seconds or less 1 to 30min 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX11144 ON-delay AC type *[No return] You cannot return this product. For details, see FAQ. 1PC 1 S1DX-A2C30M-AC120V 35286562 48.99 SGD
Shipped after 2019-06-03
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC100-120 - Plug-in termination Initial / 100 or less (at DC6V1A) 0.1 seconds or less 3 to 60s 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX11114 ON-delay AC type   1PC 1 S1DX-A2C60S-AC120V 35286535 48.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) Less than 2W -10 to +50(Non-condensing) DC24 S1DX-A2C60S-DC24V Plug-in termination Initial / 100 or less (at DC6V1A) - 3-60 seconds 980m / s <sup> 2 </ sup> (100G) or more - 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay type DC   1PC 1 ADX11012 35286851 45.99 SGD
Shipped after 2019-06-03
7A 250V AC (resistive load) Less than 2W -10 to +50(Non-condensing) DC24 S1DX-A2C3M-DC24V Plug-in termination Initial / 100 or less (at DC6V1A) - - 980m / s <sup> 2 </ sup> (100G) or more - 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay type DC *[No return] You cannot return this product. For details, see FAQ. 1PC 1 ADX11062 35286867 45.99 SGD
Shipped after 2019-06-03
7A 250V AC (resistive load) Less than 2W -10 to +50(Non-condensing) DC24 S1DX-A2C30S-DC24V Plug-in termination Initial / 100 or less (at DC6V1A) - 1-30 seconds 980m / s <sup> 2 </ sup> (100G) or more - 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay type DC   1PC 1 ADX11072 35286842 45.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) Less than 2W -10 to +50(Non-condensing) DC24 S1DX-A2C60M-DC24V Plug-in termination Initial / 100 or less (at DC6V1A) - 3 (60 minutes) 980m / s <sup> 2 </ sup> (100G) or more - 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay type DC *[No return] You cannot return this product. For details, see FAQ. 1PC 1 ADX11082 35286894 45.99 SGD
Shipped after 2019-05-31
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC200-220 - Plug-in termination Initial / 100 or less (at DC6V1A) 0.1 seconds or less 1 to 30s 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX11175 ON-delay AC type   1PC 1 S1DX-A2C30S-AC220V 35286641 48.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC100-120 - Plug-in termination Initial / 100 or less (at DC6V1A) 0.1 seconds or less 0.1 to 3min 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX11164 ON-delay AC type   1PC 1 S1DX-A2C3M-AC120V 35286544 48.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) Less than 2W -10 to +50(Non-condensing) DC24 S1DX-A2C10M-DC24V Plug-in termination Initial / 100 or less (at DC6V1A) - - 980m / s <sup> 2 </ sup> (100G) or more - 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay type DC   1PC 1 ADX11032 35286876 45.99 SGD
Shipped after 2019-05-31
7A 250V AC (resistive load) Less than 2W -10 to +50(Non-condensing) DC12 S1DX-A2C3M-DC12V Plug-in termination Initial / 100 or less (at DC6V1A) - - 980m / s <sup> 2 </ sup> (100G) or more - 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay type DC *[No return] You cannot return this product. For details, see FAQ. 1PC 1 ADX11061 35286763 45.99 SGD
Shipped after 2019-06-03
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC100-120 - Plug-in termination Initial / 100 or less (at DC6V1A) 0.1 seconds or less 1 to 30s 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX11174 ON-delay AC type   1PC 1 S1DX-A2C30S-AC120V 35286526 48.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC100-120 - Plug-in termination Initial / 100 or less (at DC6V1A) 0.1 seconds or less 0.1 to 3h 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX11194 ON-delay AC type   1PC 1 S1DX-A2C3H-AC120V 35286587 48.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC200-220 - Plug-in termination Initial / 100 or less (at DC6V1A) 0.1 seconds or less 3 to 60s 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX11115 ON-delay AC type   1PC 1 S1DX-A2C60S-AC220V 35286657 48.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) Less than 2W -10 to +50(Non-condensing) DC12 S1DX-A2C60S-DC12V Plug-in termination Initial / 100 or less (at DC6V1A) - 3-60 seconds 980m / s <sup> 2 </ sup> (100G) or more - 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay type DC   1PC 1 ADX11011 35286754 45.99 SGD
Shipped after 2019-06-03
7A 250V AC (resistive load) Less than 2W -10 to +50(Non-condensing) DC24 S1DX-A2C30M-DC24V Plug-in termination Initial / 100 or less (at DC6V1A) - - 980m / s <sup> 2 </ sup> (100G) or more - 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay type DC *[No return] You cannot return this product. For details, see FAQ. 1PC 1 ADX11042 35286885 45.99 SGD
Shipped after 2019-06-03
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC100-120 - Plug-in termination Initial / 100 or less (at DC6V1A) - 0.05 to 0.5s 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX111A4 ON-delay AC type *[No return] You cannot return this product. For details, see FAQ. 1PC 1 S1DX-A2C0.5S-AC120V 35286474 48.99 SGD
Shipped after 2019-06-03
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC200-220 - Plug-in termination Initial / 100 or less (at DC6V1A) 0.1 seconds or less 1 to 30min 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX11145 ON-delay AC type *[No return] You cannot return this product. For details, see FAQ. 1PC 1 S1DX-A2C30M-AC220V 35286684 48.99 SGD
Shipped after 2019-05-31
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC100-120 - Plug-in termination Initial / 100 or less (at DC6V1A) - 3 to 60min 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more ADX11184 ON-delay AC type *[No return] You cannot return this product. For details, see FAQ. 1PC 1 S1DX-A2C60M-AC120V 35286571 48.99 SGD
Shipped after 2019-05-27
7A 250V AC (resistive load) Less than 2W -10 to +50(Non-condensing) DC24 S1DX-A2C5S-DC24V Plug-in termination Initial / 100 or less (at DC6V1A) - - 980m / s <sup> 2 </ sup> (100G) or more - 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay type DC *[No return] You cannot return this product. For details, see FAQ. 1PC 1 ADX110E2 35286824 45.99 SGD
Shipped after 2019-06-03
7A 250V AC (resistive load) 3VA following -10 to +50(Non-condensing) AC200-220 S1DX-A2C3S-AC220V Plug-in termination Initial / 100 or less (at DC6V1A) 0.1 seconds or less 0.1 to 3 seconds 980m / s <sup> 2 </ sup> (100G) or more For both 50 and 60 80 to 85%RH(at20deg C) 98m / s <sup> 2 </ sup> (10G) more - ON-delay AC type   1PC 1 ADX11125 35286614 48.99 SGD
Shipped after 2019-05-27
7A 250 V AC (RESISTIVE LOAD) Below 3 VA -10 to + 50 (Non-condensing) AC100-120 - Plug-in terminal INITIAL / 100 or less (DC6V1A) Less than 0.1 seconds 0.2 - 5s Above 980m/s<SUP>2</SUP> 50/60 shared use 80-85% RH (at 20 degree c) Above 98m/s<SUP>2</SUP> ADX111E4 On-delay AC type   1PC 1 S1DX-A2C5S-AC120V 35286501 48.99 SGD
Shipped after 2019-05-27
7A 250 V AC (RESISTIVE LOAD) Below 3 VA -10 to + 50 (Non-condensing) AC200-220 - Plug-in terminal INITIAL / 100 or less (DC6V1A) Less than 0.1 seconds 0.2 - 5s Above 980m/s<SUP>2</SUP> 50/60 shared use 80-85% RH (at 20 degree c) Above 98m/s<SUP>2</SUP> ADX111E5 On-delay AC type   1PC 1 S1DX-A2C5S-AC220V 35286623 48.99 SGD
Shipped after 2019-05-27
ADD TO CART
Customer Reviews
5 star 10
4 star 2
3 star 2
2 star 0
1 star 0
Review Rating: 4.57
14 Customer Reviews
The reviews are automatic translation.
Parts in the autoclave circuit
5
From Japan
On 2019-03-05 20:55:44
It was exchange from the old type, but was usable without a problem in particular.
This review is about item#35286544.
Machine maintenance
4
From Japan
On 2019-01-05 08:20:24
Since the former was made by Panasonic 27 years ago, it was hard to set up because it was a volume scale rather than a number, but it was replaced in 1 minute. In the trial run of the machine, the first start was surprised at the feed motor being jerky!
This review is about item#35286492.
When the output of 12V inverter of solar power generation is overloaded, start and stop are repeated.
5
From Japan
On 2018-10-29 13:16:23
12V inverter starts up even though the 12V storage battery is not fully recovered. Use this on-delay to give recovery time of about 10 minutes. I am satisfied because I have achieved the required purpose.
This review is about item#35286571.
Used for thermal wire welding machine without timer
3
From Japan
On 2018-09-01 15:32:47
Used to thermally weld plastic bags etc using electric wire. Because it was a type with no timer attached, I adopted ESWAN. Even if you do not produce DC 5 V with an AC adapter, we are adopting it to various AC 100 V devices because it keeps accurate time. I am also using it for my own photosensitive substrate exposure machine.
This review is about item#35286517.
Used for OFF timer of garage lighting.
5
From Japan
On 2017-12-22 07:07:39
When my car enters the night garage, the lights are automatically turned on, but it is used to set the time until the lights are turned off automatically. I am working everyday, but it is stable. Time is also accurate.
This review is about item#35286781.
During machine maintenance
5
From Japan
On 2017-05-09 14:49:11
It was very helpful to purchase the same thing as the failed timer. I think that the price is also profitable.
This review is about item#35286684.
Replacement of old model number
5
From Japan
On 2017-04-29 20:38:18
Since it was using the old model number National, if you can post without any problems, you can save the old part number at the same time
This review is about item#35286614.
Startup time of the irrigation distribution and distribution pump
3
From Japan
On 2017-03-21 17:04:40
Although I was using the ADX 1195, the notation color of the operation LED, which is related to the operation failure and was involved, was different from the previous one
This review is about item#35286702.
Relay control circuit
5
From Japan
On 2017-01-24 10:47:15
It is a timer relay that is readily available and easy to use. I would like you to post the fact that you need separate leaf springs to the DIN terminal block.
This review is about item#35286517.
Machine control
4
From Japan
On 2015-01-02 22:00:56
I am pretty precise and satisfied.
This review is about item#35286684.